Now you have the ability to receive binSight - Bin assignments from PLC.

Setup

In AGRIS go to ONE > Setup Information > Workstation Information > binSight tab.

Select the Remote Bin Assignment checkbox. Enter Serial Port parameters for the Communication Port. (The Communication Port is listed in ONE > Setup Information > Connection Summary).

Usage

When going into Ticket Entry, the Communication Port is opened and the program listens for text input on that port.

The format of the text it listens for is [Sample Number], [Bin Name], [Bin ID] <CR><LF>.

Processing is in the background - it does not move focus to the ticket to update. If it is the current ticket, the new bin assignment will be visible in the bin assignment grid the next time the ticket is saved.

The PLC Interface extended option (ONE #5) must be on to use this feature.

If there is one or more assigned bins on the ticket, the first bin assignment is replaced with the one sent by the PLC and the assigned quantity remains the same.