AGRIS Customer Documentation
Error Message: Basic -2147467259 (AeData:clsAeData:AeDBLogin) the file specified is not a Btrieve file (Btrieve Error 30)
When accessing a copied dataset from a Standaloneother location the following error message is displayed:
BASIC #-2147467259 (AeData:clsAeData:AeDBLogin)
[Pervasive][ODBC Client Interface][LNA][Pervasive][ODBC Engine Interface][Data Record Manager]The file specified is not a Btrieve file or was created by a later version of Btrieve.(Btrieve Error 30)
Open the Problem Dataset Folder
]]>Look for the file: pvsw.loc
If this file exists the Dataset was accessed during the Copy
Obtain a new copy of the dataset, making sure that it is not accessed during the copy
Replace the Damaged Dataset
NOTE: If the error appears prior to the Select Dataset screen, it will prevent the workstation from accessing AGRIS. To access AGRIS from this workstation, delete the workstation from AGRIS.
From another computer access AGRIS - Customize - Workstations
From the list find the workstation experiencing the problem and select it
Press the Delete key on the keyboard
Select 'Yes' to remove the workstation
Start AGRIS on the problem machine
Select a Valid Dataset
Reconfigure the Workstation Setup (default printers, etc)
3820 Mansell Road, Suite 350 ✦ Alpharetta, GA 30022 ✦ www.GreenstoneSystems.com