Update the C:\Agris\Agris.ini file to point to the correct datapath.
Double-click on My Computer, C: drive, Agris
In the Agris folder, double-click the Agris.ini (looks like a notepad and is the only file in the folder that says 'Agris')
Scroll to the very bottom of the file and find the following section
[Paths]
Data Path=
Support Path=
Userprog Path=
Work Path=
Component Server=
Locking ServerNOTE: Lines should not begin with a semicolon [;]
Change the 'Data Path=' line so that it looks like \\Server_Name\Apps\Agris\Datasets (where Server_Name is the actual name of your server)
Click on File > Exit
Do you want to save the changes? - Click 'Yes'
AGRIS should now function properly.
Comments
This has also been observed on occasion when a machine functioning as a client (not the machine where the data is at and no ability to function in offline mode) has the PSQL Workgroup installed. In such cases, uninstalling PSQL Workgroup and installing PSQL Client on the machine functioning as a client has resolved the 3014 error.