AGRIS Customer Documentation
Error -2147467261 Fetching Agrian Data
When going to AGY - General Setup - Items - Chemical you get the following error
Agrian utilizes IIS and ASP.NET across the network and therefore requires a functional Internet connection to communicate with these services on the server. If everything is setup and functioning on the server, but you get the above error from the client, it is an indication that the Internet connectivity is not configured properly.
I. This may be caused by incorrect proxy settings.
On the client exhibiting the problem, check the following:
Launch Internet Explorer
Click on the Tools menu item
Click on Internet Options
Click the Connections tab
Click the LAN settings button
Click to uncheck "Use a proxy server for your LAN" if a proxy is not required or if a proxy is required confirm the settings that need to be set with the Network Administrator
Click OK
Click Apply
Click OK
Close Internet Explorer
II. This has also been observed on certain client machines that use a mapped network drive instead of a UNC path to the datasets folder on the server.
To test the changes proceed with the following:
Launch AGRIS
Select your dataset and sign in
Click AGY button
Click General Setup
Click Items - Chemical
If it proceeds to the Chemical Maintenance window without an error Agrian is functioning correctly
3820 Mansell Road, Suite 350 ✦ Alpharetta, GA 30022 ✦ www.GreenstoneSystems.com